Tripp Lite SU16KRT uninterruptible power supply (UPS) Double-conversion (Online) 16 kVA 14400 W 10 AC outlet(s)

Tripp Lite SU16KRT. UPS topology: Double-conversion (Online), Output power capacity: 16 kVA, Output power: 14400 W. AC outlet types: C19 coupler, NEMA L6-30R, AC outlets quantity: 10 AC outlet(s). Typical backup time at full load: 5.5 min, Typical backup time at half load: 13.5 min. Form factor: Rackmount/Tower, Product color: Black, Housing material: Steel. Width: 17.5" (445 mm), Depth: 25.8" (656 mm), Height: 5.16" (131 mm)
Manufacturer: Tripp Lite
Availability: Out of Stock - on backorder and will be dispatched once in stock.
SKU: 2783443
Manufacturer part number: SU16KRT
MSRP: $17,344.08
$12,232.77
Tripp Lite SU16KRT 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations. - Tripp Lite SU16KRT 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 12U total rack/tower configuration - Unique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and under - Included Parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level - Hardwire input; 2 L6-30R and 8 C19 outlets - Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal - Supports 50/60Hz operation for worldwide frequency compatibility - Expandable runtime with optional external battery packs - Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) - Battery independent restart
Tripp Lite SU16KRT 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations. - Tripp Lite SU16KRT 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 12U total rack/tower configuration - Unique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and under - Included Parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level - Hardwire input; 2 L6-30R and 8 C19 outlets - Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal - Supports 50/60Hz operation for worldwide frequency compatibility - Expandable runtime with optional external battery packs - Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) - Battery independent restart
Products specifications
Attribute nameAttribute value
Depth25.8"
Package width40.3"
AC outlet typesC19 coupler, NEMA L6-30R
CertificationUL1778, CSA, FCC, IEC
Master (outer) case width40.3"
Height5.16"
Weight43 lbs
Emergency Power Off (EPO)Y
Package depth51"
Package height36"
Package weight601 lbs
Rack capacity12U
AC outlets quantity10 AC outlet(s)
Output power capacity16 kVA
Output power14400 W
Noise level60 dB
Typical backup time at full load5.5 min
Typical backup time at half load13.5 min
Input operation voltage (max)300 V
Output operation voltage (min)200 V
Power protection featuresOver voltage, Under voltage
Power factor0.9
Master (outer) case weight601 lbs
Master (outer) case length51"
Master (outer) case height36"