Tripp Lite PDUBHV20D power distribution unit (PDU) 4 AC outlet(s) 2U Black

Tripp Lite PDUBHV20D. Rack capacity: 2U, Type: Single-phase, Mounting: Horizontal. AC outlets quantity: 4 AC outlet(s), AC outlet types: Type E, Power plug: Type E. Nominal input voltage: 220 - 240 V, Maximum current: 16 A, Output voltage: 220 - 240 V. Width: 17.2" (437.9 mm), Depth: 3.94" (100.1 mm), Height: 2.21" (56.1 mm). Package weight: 7.21 lbs (3.27 kg), Package width: 8.1" (205.7 mm), Package depth: 21.4" (543.6 mm)
Manufacturer: Tripp Lite
Availability: Out of Stock - on backorder and will be dispatched once in stock.
SKU: 6365652
Manufacturer part number: PDUBHV20D
MSRP: $211.54
$149.20
Bypass PDU Recommended for Maintaining Continuous Power During UPS Maintenance Keeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 220-240V 16A single-phase hot-swap PDU works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDU’s bypass switch, permitting maintenance or equipment replacement with no interruption of performance. Features Dual Inputs and a Manual Transfer Switch for Uninterrupted Operation The PDUBHV20D features two C20 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the four Schuko outlets will continue to operate without interruption. Optional ECO Switching Feature Enables Cost-Cutting Power Savings By enabling the ECO power saving feature, you can power off a single bank of three controlled Schuko outlets all at once when the device connected to the master Schuko outlet is powered off or goes into a low-power consumption mode. Mounts into 2U of Rack Space or on a Wall Use the included mounting hardware to install the PDUBHV20D’s all-metal housing inside a 19-inch rack. Because the PDU’s 56.1-millimeter height is larger than 1U in an EIA-standard rack, you will need to mount the unit into 2U of space. You may also use the mounting brackets to secure the PDU to a wall.
  • Ideal for supporting critical IT equipment that require 24/7/365 uptime
  • Transfers connected components to utility power with no downtime during UPS maintenance
  • Dual C20 inlets support connection to separate UPS and utility input power sources
  • ECO mode saves power by shutting down controlled outlet bank in certain conditions
  • Mounts into 2U of rack space or onto wall using included mounting hardware
Bypass PDU Recommended for Maintaining Continuous Power During UPS Maintenance Keeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 220-240V 16A single-phase hot-swap PDU works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDU’s bypass switch, permitting maintenance or equipment replacement with no interruption of performance. Features Dual Inputs and a Manual Transfer Switch for Uninterrupted Operation The PDUBHV20D features two C20 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the four Schuko outlets will continue to operate without interruption. Optional ECO Switching Feature Enables Cost-Cutting Power Savings By enabling the ECO power saving feature, you can power off a single bank of three controlled Schuko outlets all at once when the device connected to the master Schuko outlet is powered off or goes into a low-power consumption mode. Mounts into 2U of Rack Space or on a Wall Use the included mounting hardware to install the PDUBHV20D’s all-metal housing inside a 19-inch rack. Because the PDU’s 56.1-millimeter height is larger than 1U in an EIA-standard rack, you will need to mount the unit into 2U of space. You may also use the mounting brackets to secure the PDU to a wall.
  • Ideal for supporting critical IT equipment that require 24/7/365 uptime
  • Transfers connected components to utility power with no downtime during UPS maintenance
  • Dual C20 inlets support connection to separate UPS and utility input power sources
  • ECO mode saves power by shutting down controlled outlet bank in certain conditions
  • Mounts into 2U of rack space or onto wall using included mounting hardware
Products specifications
Attribute nameAttribute value
Weight4.32 lbs
Master (outer) case GTIN (EAN/UPC)10037332253122
Master (outer) case weight31.1 lbs
Height2.21"
Packaging data
Package width8.1"
Package depth21.4"
Package weight7.21 lbs
Operational conditions
Storage temperature (T-T)-30 - 50 °C
Power
Nominal input voltage220 - 240 V
Maximum power3800 W
Features
Output voltage220 - 240 V