CyberPower OL8KRT uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA 8000 W 4 AC outlet(s)

CyberPower OL8KRT. UPS topology: Double-conversion (Online), Output power capacity: 8 kVA, Output power: 8000 W. AC outlet types: NEMA L6-30R, Terminal, AC outlets quantity: 4 AC outlet(s), USB port type: USB Type-B. Battery technology: Sealed Lead Acid (VRLA), Battery capacity: 9 Ah, Battery voltage: 12 V. Form factor: Rackmount/Tower, Product color: Black, Housing material: Steel. Width: 17" (433 mm), Depth: 26" (660 mm), Height: 10.5" (266 mm)
Manufacturer: CyberPower
SKU: 5313446
Manufacturer part number: OL8KRT
MSRP: $6,759.00
$6,518.78
The CyberPower Smart App Online OL8KRT is a 6U rack/tower UPS with double-conversion. It provides sine wave output to multiple types of critical IT infrastructure requiring seamless power protection. The OL8KRT is generator compatible and delivers consistent 200-240 V power with zero-transfer time. Automatic-bypass ensures connected equipment continues to operate seamlessly when an overload or internal fault is detected. The OL8KRT features a removable LCD control panel to reposition it in a more convenient location (with optional DB-26 cable), and it has a RMCARD205 pre-installed network card. Smart-battery management charging technology increases battery life by up to 50%. Fast-charge technology helps replenish battery charge from 0-90% in five hours, regardless of the number of Extended Battery Modules (EBM) connected. The energy-saving GreenPower UPS™ ECO Mode allows the UPS to reach up to 96% efficiency to reduce power consumption and thermal dissipation. This UPS can use the BP240V30ART3U or BP240VL3U01 extended battery module for more runtime. The OL6KRT comes with a three-year warranty (including batteries) and a $300,000 connected equipment guarantee. Double-Conversion Topology Provides consistent, clean, and nearly perfect sine wave output power, regardless of the condition of input power. UPS systems with this technology operate on isolated DC power 100% of the time and have a zero-transfer time because they electronically switch to battery (vs. using relays which can take 4-12 ms to switch). Double-conversion UPS systems are designed for high-availability applications, precise output voltage regulation (±2%), generator set compatibility, environments with poor power quality, and other sensitive electronic equipment. Sine Wave Output Provides power protection to ENERGY STAR® 6.0 systems with Active PFC power supplies. Removable LCD Control Panel Panel displays 24 UPS status readings and allows configuration of 27 operation settings. The onboard event log will record and display the five most recent UPS system events. The LCD control panel can be removed and mounted in a more convenient location, up to ten feet away from the UPS (with optional DB-26 cable). Users can manage, setup, and control various operation settings, can scroll through multiple UPS status readings, and can run select UPS diagnostic tests. Multiple Language Options The LCD control panel can be configured to English, Spanish, French, or German for use in multiple countries. Extended Battery Module (EBM) Add runtime by connecting more EBMs. The Smart App Online series of UPS systems allow for up to ten EBMs to be connected in a daisy-chain. Fast Charge Technology Enables Smart App Online UPS systems with multiple EBMs to charge batteries from 0-90% capacity in five hours. This is possible thanks to the built-in charger in each EBM. Smart Battery Management (SBM) Extends the service life of Smart App Online UPS batteries and reduces excessive heat during charge cycles by using a three-stage charging process. The first stage charges the battery to full capacity. The second stage enters float mode. The third stage turns the charger OFF to allow the batteries to naturally discharge (rest) for up to 27 days or until they reach a low-voltage set point. SBM continuously monitors the UPS to restart the charge cycle as needed, ensuring that runtimes are maintained. GreenPower UPS™ ECO Mode Improves UPS efficiency up to 96% to reduce electrical and cooling costs. Hot-Swappable Batteries Eliminate downtime related to UPS maintenance for continuous power availability. Generator Compatible Mode of operation in which the UPS disregards rapid changes in input frequency like those found in the output waveform of some generator sets. This allows the UPS to continue to operate in normal Online Mode vs. switching to Battery Mode when the power source is a generator set. Converter Mode Provides the ability to set the UPS output frequency (50 Hz or 60 Hz), regardless of the input frequency. This is beneficial where the connected equipment must operate on a different frequency than provided by local electric utility. Local and Remote Management Monitor and manage the UPS system locally via USB or serial connection, or remotely via the pre-installed RMCARD205 network card. Access UPS status, configuration settings, event logs, and status records, and more. User can also setup email notifications. Rack or Tower Installation All the hardware accessories to rack mount the UPS in a standard 4-post 19” rack, or install as a tower unit, is included at no extra cost. PowerPanel® Business Edition Software A robust and feature rich power monitoring and management tool for physical or virtual environments, PowerPanel Business Edition offers local (Agent) or remote (Client) functionality to automate graceful shutdown of IT equipment. Installing PowerPanel Business Edition Center provides centralized monitoring and management of PPBE Agents and Clients on the local network in addition to all CyberPower devices. PPBE is FREE for download on the Downloads tab above. Three-Year Warranty CyberPower will repair or replace a defective UPS system (including batteries) within three years of the purchase date. Connected Equipment Guarantee CyberPower will repair or replace properly connected equipment if it is damaged by a power surge.

 

  • 8,000 V / 8,000 W
  • Double Conversion Topology
  • Sine Wave Output, Zero Transfer Time
  • Output: 200-240 V
  • GreenPower UPS™ ECO Mode
  • Removable LDC Control Panel
  • Generator Compatibility Mode
The CyberPower Smart App Online OL8KRT is a 6U rack/tower UPS with double-conversion. It provides sine wave output to multiple types of critical IT infrastructure requiring seamless power protection. The OL8KRT is generator compatible and delivers consistent 200-240 V power with zero-transfer time. Automatic-bypass ensures connected equipment continues to operate seamlessly when an overload or internal fault is detected. The OL8KRT features a removable LCD control panel to reposition it in a more convenient location (with optional DB-26 cable), and it has a RMCARD205 pre-installed network card. Smart-battery management charging technology increases battery life by up to 50%. Fast-charge technology helps replenish battery charge from 0-90% in five hours, regardless of the number of Extended Battery Modules (EBM) connected. The energy-saving GreenPower UPS™ ECO Mode allows the UPS to reach up to 96% efficiency to reduce power consumption and thermal dissipation. This UPS can use the BP240V30ART3U or BP240VL3U01 extended battery module for more runtime. The OL6KRT comes with a three-year warranty (including batteries) and a $300,000 connected equipment guarantee. Double-Conversion Topology Provides consistent, clean, and nearly perfect sine wave output power, regardless of the condition of input power. UPS systems with this technology operate on isolated DC power 100% of the time and have a zero-transfer time because they electronically switch to battery (vs. using relays which can take 4-12 ms to switch). Double-conversion UPS systems are designed for high-availability applications, precise output voltage regulation (±2%), generator set compatibility, environments with poor power quality, and other sensitive electronic equipment. Sine Wave Output Provides power protection to ENERGY STAR® 6.0 systems with Active PFC power supplies. Removable LCD Control Panel Panel displays 24 UPS status readings and allows configuration of 27 operation settings. The onboard event log will record and display the five most recent UPS system events. The LCD control panel can be removed and mounted in a more convenient location, up to ten feet away from the UPS (with optional DB-26 cable). Users can manage, setup, and control various operation settings, can scroll through multiple UPS status readings, and can run select UPS diagnostic tests. Multiple Language Options The LCD control panel can be configured to English, Spanish, French, or German for use in multiple countries. Extended Battery Module (EBM) Add runtime by connecting more EBMs. The Smart App Online series of UPS systems allow for up to ten EBMs to be connected in a daisy-chain. Fast Charge Technology Enables Smart App Online UPS systems with multiple EBMs to charge batteries from 0-90% capacity in five hours. This is possible thanks to the built-in charger in each EBM. Smart Battery Management (SBM) Extends the service life of Smart App Online UPS batteries and reduces excessive heat during charge cycles by using a three-stage charging process. The first stage charges the battery to full capacity. The second stage enters float mode. The third stage turns the charger OFF to allow the batteries to naturally discharge (rest) for up to 27 days or until they reach a low-voltage set point. SBM continuously monitors the UPS to restart the charge cycle as needed, ensuring that runtimes are maintained. GreenPower UPS™ ECO Mode Improves UPS efficiency up to 96% to reduce electrical and cooling costs. Hot-Swappable Batteries Eliminate downtime related to UPS maintenance for continuous power availability. Generator Compatible Mode of operation in which the UPS disregards rapid changes in input frequency like those found in the output waveform of some generator sets. This allows the UPS to continue to operate in normal Online Mode vs. switching to Battery Mode when the power source is a generator set. Converter Mode Provides the ability to set the UPS output frequency (50 Hz or 60 Hz), regardless of the input frequency. This is beneficial where the connected equipment must operate on a different frequency than provided by local electric utility. Local and Remote Management Monitor and manage the UPS system locally via USB or serial connection, or remotely via the pre-installed RMCARD205 network card. Access UPS status, configuration settings, event logs, and status records, and more. User can also setup email notifications. Rack or Tower Installation All the hardware accessories to rack mount the UPS in a standard 4-post 19” rack, or install as a tower unit, is included at no extra cost. PowerPanel® Business Edition Software A robust and feature rich power monitoring and management tool for physical or virtual environments, PowerPanel Business Edition offers local (Agent) or remote (Client) functionality to automate graceful shutdown of IT equipment. Installing PowerPanel Business Edition Center provides centralized monitoring and management of PPBE Agents and Clients on the local network in addition to all CyberPower devices. PPBE is FREE for download on the Downloads tab above. Three-Year Warranty CyberPower will repair or replace a defective UPS system (including batteries) within three years of the purchase date. Connected Equipment Guarantee CyberPower will repair or replace properly connected equipment if it is damaged by a power surge.

 

  • 8,000 V / 8,000 W
  • Double Conversion Topology
  • Sine Wave Output, Zero Transfer Time
  • Output: 200-240 V
  • GreenPower UPS™ ECO Mode
  • Removable LDC Control Panel
  • Generator Compatibility Mode
Products specifications
Attribute nameAttribute value
Battery recharge time (90%)5 h
Overload capacity (1 minute)125 %
Overload capacity (10 seconds)130 %
Weight227.1 lbs
Input power factor0.99
Output power factor1
Width17"
Depth26"
Height10.5"
Housing MaterialSteel
Battery Capacity9 Ah
Emergency Power Off (EPO)Y
Input Frequency40 - 70 Hz
Display TypeLCD
Quick installation guideY
UPS topologyDouble-conversion (Online)
Serial interfaceY
ECO modeY
Output frequency50/60 Hz
Rack mount kitY
EMI/RFI noise filteringY
Cold startY
Crest factor3:1
Emergency Power Off (EPO) connectorY
USB port typeUSB Type-B
Efficiency (ECO mode)96 %
Technical details
Product colorBlack
Sustainability certificatesRoHS
Serial interface typeRS-232
Ports & interfaces
AC outlet typesNEMA L6-30R, Terminal
Modem (RJ-11) ports2
AC outlets quantity4 AC outlet(s)
Ethernet LAN (RJ-45) ports2
RS-232 ports1
USB 2.0 ports quantity1
USB portY
Design
Form factorRackmount/Tower
Operational conditions
Storage temperature (T-T)-20 - 45 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)0 - 90 %
Storage relative humidity (H-H)0 - 95 %
Operating altitude0 - 118110.2"
Non-operating altitude0 - 590551.2"
Power
Power protection featuresOverload, Short circuit
Output power capacity8 kVA
Features
SafetyUL 1778 5th Ed., CSA C22.2 NO.107.3-05, FCC 5 A
Output power8000 W
Noise level65 dB
Input operation voltage (max)280 V
Audible alarm modesAlarm when on battery, Fault, Low battery alarm, Overload alarm
Rack capacity6U
LED indicatorsY
Audible alarm(s)Y
Surge energy rating2430 J
Input operation voltage (min)120 V
Output operation voltage (min)200 V
Output operation voltage (max)240 V
WaveformSine
Other features
Number of batteries supported20
Packaging content
Cables includedPhone (RJ-11), Serial, USB cable
Battery
Typical backup time at full load4.7 min
Battery technologySealed Lead Acid (VRLA)
Typical backup time at half load12 min
Hot-swap batteryY
Battery voltage12 V
Ergonomics