CyberPower OL2200RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA 1800 W 7 AC outlet(s)

CyberPower OL2200RTXL2UN. UPS topology: Double-conversion (Online), Output power capacity: 2.2 kVA, Output power: 1800 W. AC outlet types: NEMA 5–20R,NEMA L5-20R, Power plug: NEMA 5-20P, AC outlets quantity: 7 AC outlet(s). Battery technology: Sealed Lead Acid (VRLA), Battery capacity: 9 Ah, Battery voltage: 12 V. Form factor: Rackmount/Tower, Product color: Black, Housing material: Metal. Width: 17" (432 mm), Depth: 23.6" (600 mm), Height: 3.5" (89 mm)
Manufacturer: CyberPower
SKU: 5468546
Manufacturer part number: OL2200RTXL2UN
MSRP: $2,219.00
$2,042.34
The CyberPower OL2200RTXL2UN is a rack/tower UPS with double conversion topology. It provides sine wave output to critical applications and equipment that require seamless power correction. The Extended Battery Module (EBM) expands runtime, and Fast Charge Technology restores full backup power faster. This model comes with an extendable LCD control panel, Smart Battery Management charging technology, and energy-saving GreenPower UPS™ ECO Mode. The OL2200RTXL2UN offers generator compatibility and delivers clean AC power with zero transfer time. A factory installed RM card allows remote management and configuration of the UPS via a standard web browser, command line interface (CLI), or network management system (NMS). Its sine wave output keeps sensitive equipment working by preventing unnecessary shutdowns that can occur with simulated sine wave output. With a $400,000 lifetime connected equipment guarantee and a three-year warranty, you can trust CyberPower’s commitment to high quality.
Double-Conversion Topology Provides consistent, clean, and nearly perfect power, regardless of the condition of the incoming power. With the conversion to DC power, the UPS has a zero millisecond transfer time to battery power when utility power is lost. Designed for high-end system components, corporate servers, lab equipment, and other sensitive electronic devices.
Sine Wave Output Keeps sensitive equipment with Active PFC working by preventing unnecessary shutdowns caused by gaps from simulated sine waves.
PowerPanel® Business Edition Software Provides tools for easy remote monitoring and managing of the UPS and automates shutdown of multiple devices when needed.
RMCARD205 Is a full-featured network management card. It enables remote management of up to 50 clients via a standard web browser, command line interface (CLI), or network management system (NMS) connection.
LCD Control Panel Displays UPS status data and configures operating settings from up to 10 ft. away (DB26 cable not included). The LCD control panel displays and allows configuration of IP address settings when an RMCARD205 is installed.
Extended Battery Module (EBM) Extends runtime by adding up to 10 EBMs.
Fast Charge Technology Allows UPS batteries to return to full capacity more rapidly by utilizing a built-in charger. Restores a complete charge within 4 hours regardless of the number of EBMs.
Smart Battery Management (SBM) Improves and extends the functional life of a UPS battery and reduces excessive heat during work cycles by using a three-cycle charging process.
GreenPower UPS™ ECO Mode Improves UPS efficiency up to 95% reducing electrical and cooling costs.
Hot-Swappable Batteries Keep equipment running by eliminating downtime during UPS battery replacement.
Upgradeable UPS firmware Manages the unit’s features and functions.
Critical & Non-Critical Load Banks Maximize the output of the UPS by setting non-critical loads to shut off allowing additional runtime for critical load outlets.
Emergency Power Off (EPO) Allows the UPS to be shut off in the event of an emergency, when the EPO port is connected to an EPO switch.
Generator Compatible Ensures a stable sine wave output (free of harmonics and distortion) without switching to battery mode when running on generator input power.
Converter Mode Provides the flexibility to set the output frequency, regardless of the input frequency, to match connected equipment by selecting 50Hz or 60Hz output on the LCD control panel.
USB & Serial Connectivity Enables full integration with built-in power management and auto shutdown features on Windows, Linux, and VMware systems through a HID-compliant USB port and Serial port.
EMI/RFI Filters Prevent electromagnetic and radio frequency interference to ensure clean power for connected equipment.
Data Line Surge Protection Prevents power surges that traveling through telephone and Ethernet lines from causing damage to your equipment
Audible Alarms Identify when the model is running on battery power, overloaded, or has a low battery.
Resettable Circuit Breaker Interrupts an electric current in a circuit when the current becomes too high.
LED Status Lights Indicate Power On, Line Mode, Battery Mode, Bypass Mode, Fault, Replace Battery.
Rack/Tower Versatility Allows for horizontal rack or vertical tower installation.
The CyberPower OL2200RTXL2UN is a rack/tower UPS with double conversion topology. It provides sine wave output to critical applications and equipment that require seamless power correction. The Extended Battery Module (EBM) expands runtime, and Fast Charge Technology restores full backup power faster. This model comes with an extendable LCD control panel, Smart Battery Management charging technology, and energy-saving GreenPower UPS™ ECO Mode. The OL2200RTXL2UN offers generator compatibility and delivers clean AC power with zero transfer time. A factory installed RM card allows remote management and configuration of the UPS via a standard web browser, command line interface (CLI), or network management system (NMS). Its sine wave output keeps sensitive equipment working by preventing unnecessary shutdowns that can occur with simulated sine wave output. With a $400,000 lifetime connected equipment guarantee and a three-year warranty, you can trust CyberPower’s commitment to high quality.
Double-Conversion Topology Provides consistent, clean, and nearly perfect power, regardless of the condition of the incoming power. With the conversion to DC power, the UPS has a zero millisecond transfer time to battery power when utility power is lost. Designed for high-end system components, corporate servers, lab equipment, and other sensitive electronic devices.
Sine Wave Output Keeps sensitive equipment with Active PFC working by preventing unnecessary shutdowns caused by gaps from simulated sine waves.
PowerPanel® Business Edition Software Provides tools for easy remote monitoring and managing of the UPS and automates shutdown of multiple devices when needed.
RMCARD205 Is a full-featured network management card. It enables remote management of up to 50 clients via a standard web browser, command line interface (CLI), or network management system (NMS) connection.
LCD Control Panel Displays UPS status data and configures operating settings from up to 10 ft. away (DB26 cable not included). The LCD control panel displays and allows configuration of IP address settings when an RMCARD205 is installed.
Extended Battery Module (EBM) Extends runtime by adding up to 10 EBMs.
Fast Charge Technology Allows UPS batteries to return to full capacity more rapidly by utilizing a built-in charger. Restores a complete charge within 4 hours regardless of the number of EBMs.
Smart Battery Management (SBM) Improves and extends the functional life of a UPS battery and reduces excessive heat during work cycles by using a three-cycle charging process.
GreenPower UPS™ ECO Mode Improves UPS efficiency up to 95% reducing electrical and cooling costs.
Hot-Swappable Batteries Keep equipment running by eliminating downtime during UPS battery replacement.
Upgradeable UPS firmware Manages the unit’s features and functions.
Critical & Non-Critical Load Banks Maximize the output of the UPS by setting non-critical loads to shut off allowing additional runtime for critical load outlets.
Emergency Power Off (EPO) Allows the UPS to be shut off in the event of an emergency, when the EPO port is connected to an EPO switch.
Generator Compatible Ensures a stable sine wave output (free of harmonics and distortion) without switching to battery mode when running on generator input power.
Converter Mode Provides the flexibility to set the output frequency, regardless of the input frequency, to match connected equipment by selecting 50Hz or 60Hz output on the LCD control panel.
USB & Serial Connectivity Enables full integration with built-in power management and auto shutdown features on Windows, Linux, and VMware systems through a HID-compliant USB port and Serial port.
EMI/RFI Filters Prevent electromagnetic and radio frequency interference to ensure clean power for connected equipment.
Data Line Surge Protection Prevents power surges that traveling through telephone and Ethernet lines from causing damage to your equipment
Audible Alarms Identify when the model is running on battery power, overloaded, or has a low battery.
Resettable Circuit Breaker Interrupts an electric current in a circuit when the current becomes too high.
LED Status Lights Indicate Power On, Line Mode, Battery Mode, Bypass Mode, Fault, Replace Battery.
Rack/Tower Versatility Allows for horizontal rack or vertical tower installation.
Products specifications
Attribute nameAttribute value
Weight68.1 lbs
Package depth34.7"
AC outlet typesNEMA 5–20R,NEMA L5-20R
CertificationUL 1778 5th Ed. CSA C22.2 NO.107.3-05 FCC Part 15 Class A
Surge energy rating1335 J
Replacement battery cartridgeRB1290X6A
Output power factor0.82
Output frequency regulation0.25 Hz
Efficiency (ECO mode)95 %